Comprehensive & Powerful Ventilator
High-end mechanical ventilator from Northern Meditec. A wide range of standard features and options allows you to fit the Crius V6 to your needs.
Turbine Based
· Shorter triggering and inspiratory delay
· Powerful non-invasive ventilation
· Compressor Free
· Central Gas Free
· Less cost
Control
Crius V6 is a fully electronic control ventilator,
Tidal Volume
5-2000mL(Optional 2-2000mL)
A wide range of TV adjustments allows the medical team to tailor the ventilator to multiple types/needs of patients, even with NICU patients.
Ventilation Modes
Invasive Ventilation Modes:
VC-ACV, PC-ACV, PRVC, VC-SIMV, SIMV-PRVC, PC-Dual PAP, PC-APRV, CPAP/PSV, CPAP/VG, AMV/MMV, nCPAP, Apnea Ventilation
Non-Invasive Ventilation Modes:
PC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, nCPAP, CPAP/PSV, CPAP/VG, AMV/MMV, Apnea Ventilation
HFNC
Tools
· Rlung, RSBI, P0.1, PEEPi, V-CO2, PTP, Expiratory Hold, sigh, ATC, PCVR, PPS, Compliance, calibration, O2 suction, 100% O2, and more adding
· Screen Freeze and Lock
· Lung measurement tools: 3 loops;
Multi-Clinical Demands :
Departments: ICU, CCU, PACU, NICU, EICU, OR, In-Hospital Transport, etc..
Suitable for:
· Adult and pediatric intensive care
· Neonatal intensive care
· Critical care transport
· Long-term acute care
· Advanced automated adaptive assisted wide-range ventilation system with electronic
· microprocessor controlled by volume and pressure to fit for all types of patients from Neonates , Pediatrics to Adults.
· 15.6 "TFT touch screen (18.5" optional), the screen supports 360 degree rotation left and right.
· Both invasive and non-invasive modes make the unit wide applications.
· Integrated self-check system with leak check and system tightness to secure the ventilation result(POST: Power On self test).
· Automatic leakage compensation by the unit provides is giving to optimize respirator settings.
· Two Lithium batteries guarantee the unit usage up to 6 hours.
· Manual settable Inspiratory pause from 0.1-6seconds.
· The unit is with automatic triggers adjustment both on flow trigger and pressure trigger.
· The unit is with measurement of volumetric capnography of CO2 ( EtCO2 measurement function)
· AMV mode can minimize the work of breathing under the target minute ventilation.

Neonatal sensor (optional accessories)
The minimum tidal volume is 2ml. It is suitable for newborns and
even premature infants to avoid barotrauma;
Meet the needs of patients of different ages, provide individualized
treatment, more accurate and safer.
Standard EtCO2 and SpO2 interfaces
EtCO2 showed the concentration of CO2 in blood during 
ventilation, reflecting the effect of ventilation; It is an important
index to judge hyperventilation or hypoventilation.
SpO2 can directly Visual display the concentration of blood
oxygen; It is an important index to judge the function of
ventilation and air change.
Double index real-time monitoring at the same time, more
convenient, more intuitive, more secure.
High and low pressure oxygen interface
The low pressure oxygen interface can be connected to the hyperbaric
oxygen cylinder or the central oxygen supply, so that the ventilator can
provide sufficient oxygen for patients when ensuring the breathing of
mild and severe patients, so as to improve the oxygenation of patients.
The independent low-pressure oxygen interface can be connected
to the oxygen pillow or small oxygen bottle to facilitate the hospital
transportation and ensure the safety of patients.
|